The Gensys Spectrum Analyzer is a small form factor, handheld and portable spectrum analyzer based on SDR (Software Defined Radio) used to measure the spectral power. It is battery operated making it ideal for both indoor and outdoor measurements. The system can be easily configured for the desired measurement settings from an external PC/Laptop/Tablet etc via ethernet interface.


Interested in the product?

The Gensys Spectrum Analyzer is a small form factor, handheld and portable spectrum analyzer based on SDR (Software Defined Radio) used to measure the spectral power. It is battery operated making it ideal for both indoor and outdoor measurements. The system can be easily configured for the desired measurement settings from an external PC/Laptop/Tablet etc via ethernet interface.

Handheld Frequency Scanner

SYSTEM SPECIFICATIONS

# Parameter Specification
1 ADC sampling rate 480 MSPS (Actual)
60 MSPS (Effective IQ Rate)
2 ADC resolution 12 bits
3 Frequency range 70 MHz – 6 GHz
4 Full range sweep time 100 ms
5 Sweep speed 60 GHz/s
6 FFT length 32 to 8192
7 Max real time bandwidth 45 MHz
8 ADC resolution 12 bits
9 No. of channels 2Tx/2Rx
10 Rx dynamic range 60 dB
11 Extended dynamic range 85 dB
12 SFDR 60 dB (Spur removal mode)
13 Max and min input power level for Rx 132 dBuV to -23 dBuV (Gain and attenuation adjustments)
14 Resolution bandwidth(RBW) 1MHz, 500KHz, 250KHz, 100KHz, 50KHz, 25KHz, 10KHz, 5KHz, 2KHz, 1KHz
15 RBW Uncertainty 2%
16 Detectors supported Min peak Max peak Sample
17 Dwell time 100 us (Min time) 10 s (Max time)
18 Max Tx power 20 dB (External power amplifier path selected)
7 dB (without the external power amplifier path)
19 External control interface Ethernet
20 User configurable parameters in GUI Mode selection Frequency span Sweep time RBW
Peak markers
Detectors
IQ mode
Spectrogram mode
Max hold mode for spectrogram Attenuation for Tx output
Gain Control for Rx channels Attenuation control for Rx channels
21 Dimensions 102 mm X 63 mm

You can view the datasheet here or